Master Access Files (MAFs) are confidential documents that suppliers submit to the U.S. Food and Drug Administration (FDA).1 An MAF contains trade secret information about a material, component, or process, such as a coating formulation, its manufacturing process, and test data.1,2
MAFs can be used for medical device coatings, including hydrophilic coatings. While the FDA reviews the coating as part of the device’s 510(k) or Premarket Approval (PMA), the formulation remains proprietary to the coating supplier.3 The supplier provides a letter of authorization, which the device manufacturer includes in its submission.1 At Hydromer®, nearly all hydrophilic coating formulations are supported by an MAF and an in-house regulatory team.
As part of our coverage of medical device coating regulations, this article outlines the contents of a coating MAF, the function of the letter of authorization, and the role of an MAF in a 510(k) submission. Please note that an MAF does not constitute FDA approval of the coating.3 We also provide five key questions to ask a coating supplier about its MAF before making a decision. This guidance is intended to help biomedical engineers, medical device manufacturers, and procurement professionals choose the right coating partner.
Key Takeaways
- An MAF helps protect a supplier’s trade secrets while the FDA reviews a customer’s device.
- A letter of authorization is the document that links a supplier’s MAF to a customer’s submission.
- A 510(k) can incorporate the information in a coating MAF by reference.
- Please note that an MAF does not constitute FDA approval of the coating.
What Is a Master Access File (MAF)?
FDA regulations define a master file as a reference source that a person submits to the FDA.2 It may contain detailed information on a specific manufacturing facility, process, methodology, or component used in making a medical device.2 The FDA calls the device version a Master File for Devices (MAF) or a Device Master File.1 In the industry, it is also known as a Master Access File.
The organization that files it with the FDA’s Center for Devices and Radiological Health (CDRH) is called the MAF holder.1 The FDA then assigns a reference number to the file.1 An MAF should not be confused with a Drug Master File (DMF), which supports drug applications.1
Purpose of an MAF in Medical Device Regulatory Submissions
An MAF helps protect a supplier’s trade secrets while the FDA reviews a customer’s device.1 A device manufacturer often depends on another party’s product, such as an ingredient, subassembly, or accessory.1 The FDA must review data on that product, but the supplier may not want its customer to see it.1
The FDA established the device master file system to solve this problem.1 The goal is to allow a sound scientific evaluation of the device without exposing the supplier’s information.1 The information in an MAF can then be incorporated by reference in a customer’s PMA, 510(k), or investigational device exemption (IDE).1
An MAF can also be used when several submissions for different products use a common material or process.1 A medical device coating applied on many devices is one such case.
What a Coating MAF Contains
The FDA does not specify content requirements for an MAF.1 Therefore, the level of detail may vary between suppliers. However, the FDA will not accept files lacking substantive trade secret or confidential information.1
As per the FDA, a coating MAF can include the following:
- Formulation and Specifications: The synthesis, formulation, purification, and specifications of the coating chemicals and materials.1
- Manufacturing Process: The facilities, manufacturing procedures, and controls used to make the coating.1
- Recommended Processing: Information on how the coating material should be processed.3
- Biological Testing: Any biocompatibility testing already performed on the material.3
- Supplier Risk Assessment: A discussion of the chemical formulation and structure, with information on how to evaluate a device made from the material.3
How the Letter of Authorization Works
A letter of authorization is the document that links a supplier’s MAF to a customer’s submission.1 Only the MAF holder, or its designated agent, can authorize the use of the information in the file.1 Below are the steps involved:
- The Supplier Issues the Letter: The MAF holder writes the letter on its company letterhead and sends it directly to the customer, not to the FDA.1
- The Letter Names the File and the Device: It states the MAF number, the submission it supports, such as a PMA, IDE, or 510(k), and the customer’s device by generic or trade name.1
- The Customer Includes It in the Submission: The letter goes into the customer’s own submission to the FDA.1
- The FDA Refers to the MAF: The letter authorizes the FDA to include the MAF information by reference while it reviews the device.1

The MAF holder can also add restricting wording to the letter.1 Note that the authorization cannot be withdrawn once the FDA has referred to the MAF and the customer’s application has been approved.1
What an MAF Does Not Do
An MAF supports a device submission, but it has clear limits. Below are the key ones:
- It Is Not an FDA Approval: The FDA neither approves nor disapproves a master file.4 It also does not clear or approve individual materials, only the device in its final finished form.3
- It Does Not Replace Device Testing: The information in an MAF alone may not be sufficient to establish the biocompatibility of the finished device.3 It may be specific to the material and may not address device fabrication.3
- It Does Not Update Itself: The file may need an amendment when the coating is modified, and the supplier needs to notify its customers before such changes.1
- It Does Not Guarantee Clearance: A customer’s submission may be adversely affected if the MAF is incomplete or inaccurate.1
MAFs and 510(k) Submissions
A 510(k) can incorporate the information in a coating MAF by reference.1 Since October 1, 2023, a 510(k) must be submitted electronically through the FDA’s eSTAR template, unless exempted.5 The letter of authorization is attached in its Cover Letter / Letters of Reference section, which holds documents that refer to other submissions.5 FDA regulatory pathways for coated medical devices, from 510(k) to De Novo and PMA, are covered in our dedicated guide.
The FDA advises sponsors to be as specific as possible when they reference materials it has reviewed before.3 This includes the master file number and the specific test reports or data.3
The 510(k) is also affected when the coating changes after clearance. Under the FDA’s 510(k) change guidance, a change in a material’s formulation or processing is a material change, and many such changes come from the material supplier.6 For a coating, the manufacturer must then assess whether it raises new biocompatibility or coating performance concerns that call for a new 510(k).6
5 Questions to Ask a Coating Supplier About Its MAF
You should inquire about an MAF when selecting a coating partner. Consider asking the supplier the following five questions:
- Coverage: Does the MAF cover the exact coating formulation you plan to use, and which biocompatibility tests does it include?
- Letter of Authorization: How do you request the letter for your device, and how long does it take?
- Change Control: How and when will the supplier notify you before the coating or its MAF changes?
- Review Support: Who answers the FDA’s questions about the file during your review?
- Other Markets: What documentation does the supplier provide for submissions outside the US?
Hydromer®: Hydrophilic Coating Manufacturer With MAFs on File
Selecting a coating partner also involves selecting the MAF your submission will reference. At Hydromer®, we have over 40 years of experience formulating hydrophilic coatings for medical devices, with MAFs available for nearly all our coating types. Our portfolio includes UV-curable, thermal-curable, and anti-thrombogenic hydrophilic coatings.
Our in-house regulatory team provides support when you reference these files in a 510(k), PMA, or IDE. We conduct biocompatibility testing according to ISO 10993, and our production facility is FDA-registered and certified to ISO 13485:2016 and ISO 9001:2015.
Please feel free to contact Hydromer® to learn more about our hydrophilic coatings and their MAFs, or to request samples.
FAQ
FDA regulations define a master file as a reference source that a person submits to the FDA. It may contain detailed information on a specific manufacturing facility, process, methodology, or component used in making a medical device.
The FDA does not specify content requirements for an MAF. Therefore, the level of detail may vary between suppliers. However, the FDA will not accept files lacking substantive trade secret or confidential information.
A letter of authorization is the document that links a supplier’s MAF to a customer’s submission. Only the MAF holder, or its designated agent, can authorize the use of the information in the file.
The FDA neither approves nor disapproves a master file. It also does not clear or approve individual materials, only the device in its final finished form.
The information in an MAF alone may not be sufficient to establish the biocompatibility of the finished device. It may be specific to the material and may not address device fabrication.
A 510(k) can incorporate the information in a coating MAF by reference. Since October 1, 2023, a 510(k) must be submitted electronically through the FDA’s eSTAR template. The letter of authorization is attached in its Cover Letter / Letters of Reference section, which holds documents that refer to other submissions.
An MAF should not be confused with a Drug Master File (DMF), which supports drug applications.
Editorial & Technical Review Board
To ensure the highest standards of engineering precision and scientific accuracy, this article was reviewed, validated, and approved by:
- Mike Torti, Chief Executive Officer
- Anthony Millan, Senior Technical Product Manager
- Paul McCue, Vice President – International Business Development
References
View All References (6 FDA & Regulatory Sources)
1. U.S. Food and Drug Administration. Device Master Files. Silver Spring, MD: FDA; 2023. https://www.fda.gov/medical-devices/premarket-submissions-selecting-and-preparing-correct-submission/device-master-files
2. Office of the Federal Register. Code of Federal Regulations, Title 21, Section 814.3, Definitions. Washington, DC: National Archives and Records Administration; 2026. https://www.ecfr.gov/current/title-21/chapter-I/subchapter-H/part-814/subpart-A/section-814.3
3. U.S. Food and Drug Administration. Use of International Standard ISO 10993-1, “Biological evaluation of medical devices – Part 1: Evaluation and testing within a risk management process”: Guidance for Industry and Food and Drug Administration Staff. Silver Spring, MD: FDA; September 2023. https://www.fda.gov/media/142959/download
4. U.S. Food and Drug Administration, Center for Biologics Evaluation and Research. SOPP 8301: Receipt and Processing of Master Files, Version 5. Silver Spring, MD: FDA; May 2026. https://www.fda.gov/media/158382/download
5. U.S. Food and Drug Administration. Electronic Submission Template for Medical Device 510(k) Submissions: Guidance for Industry and Food and Drug Administration Staff. Silver Spring, MD: FDA; October 2023. https://www.fda.gov/media/152429/download
6. U.S. Food and Drug Administration. Deciding When to Submit a 510(k) for a Change to an Existing Device: Guidance for Industry and Food and Drug Administration Staff. Silver Spring, MD: FDA; October 2017. https://www.fda.gov/media/99812/download